gluon/patches/openwrt/0063-ar71xx-don-t-use-D-Link-DIR-505-status-LED-as-ethernet-indicator.patch

29 lines
1.1 KiB
Diff
Raw Normal View History

From: Matthias Schiffer <mschiffer@universe-factory.net>
Date: Thu, 28 Jul 2016 15:59:04 +0200
Subject: ar71xx: don't use D-Link DIR-505 status LED as ethernet indicator
The stock firmware uses the single LED as status indicator only. Using the
same LED both for status and as ethernet indicator is uncommon, and has
been confusing users who were using the device as a WLAN mesh node (so the
LED was just off, as no ethernet was connected).
Signed-off-by: Matthias Schiffer <mschiffer@universe-factory.net>
Backport of LEDE adbbfb7ff900c489e6be34b2ec2834172dff7943
diff --git a/target/linux/ar71xx/base-files/etc/uci-defaults/01_leds b/target/linux/ar71xx/base-files/etc/uci-defaults/01_leds
index 9a0d7eb..7c18346 100644
--- a/target/linux/ar71xx/base-files/etc/uci-defaults/01_leds
+++ b/target/linux/ar71xx/base-files/etc/uci-defaults/01_leds
@@ -132,10 +132,6 @@ dhp-1565-a1)
ucidef_set_led_switch "wan" "WAN" "d-link:green:planet" "switch0" "0x20"
;;
-dir-505-a1)
- ucidef_set_led_netdev "lan" "LAN" "d-link:green:power" "eth1"
- ;;
-
dir-600-a1|\
dir-615-e1|\
dir-615-e4)