Commit Graph

37 Commits

Author SHA1 Message Date
bobcanthelpyou
4249d65af7 treewide: fix luacheck warnings 2019-06-16 22:51:53 +02:00
Matthias Schiffer
da45bd5987
treewide: do not use Lua module() 2019-06-16 15:51:43 +02:00
Linus Lüssing
9b1eb40fe7 gluon-mesh-batman-adv: reenable batman-adv multicast optimizations
Several fixes and enhancements related to multicast were added upstream
in batman-adv. So let's give the batman-adv multicast optimizations
another go.

Signed-off-by: Linus Lüssing <linus.luessing@c0d3.blue>
2019-06-07 15:16:40 +02:00
Matthias Schiffer
09916f6e35
gluon-mesh-batman-adv: drop packets from mesh with next-node source or destination address (#1714)
Fixes #1659
2019-04-28 14:56:09 +02:00
Linus Lüssing
8e04679be6 gluon-mesh-batman-adv: add batctl dependency to gluon-mesh-batman-adv-14
The batctl v2013.4 build was removed from the batman-adv-legacy package
as the current, upstream batctl releases work with batman-adv-legacy,
too.

As a replacement we need to add the upstream batctl dependency to
gluon-mesh-batman-adv-14 to have a batctl available again here.

Signed-off-by: Linus Lüssing <linus.luessing@c0d3.blue>
2019-04-16 12:03:20 +02:00
Sven Eckelmann
cef21e584a gluon-mesh-batman-adv: Save if metrics chose neighbor as own best nexthop
The commit ee63ed42fe ("gluon-mesh-batman-adv: List neighbors with
non-best direct link") removed the check whether a neighbor has the
BATADV_ATTR_FLAG_BEST set. But consumers may still want to filter out or
mark neighbors which don't have this flag set. To assist with such a
feature, enhance the neighbor object with an extra boolean "best" attribute
which stores whether the BATADV_ATTR_FLAG_BEST was found or not.

Reported-by: Vincent Wiemann <webmaster@codefetch.de>
2019-04-09 01:31:51 +02:00
Sven Eckelmann
ec72d30b8f gluon-mesh-batman-adv: List neighbors with non-best direct link
Links between two direct neighbors are not always the best route between
these devices. The flag BATADV_ATTR_FLAG_BEST would not be set for these
originator entries and the respondd module would just ignore this entry.

This causes missing links in meshviewer and similar tools. And when the
link quality is nearly equal and but fluctuates slightly, these links will
from time to time appear and disappear on the map.

Fixes: 2e0e24a992 ("announce neighbours using alfred/gluon-announce")
2019-04-09 01:31:51 +02:00
Sven Eckelmann
b850fff7e4 gluon-mesh-batman-adv: Only use local TT to count non-wifi clients (#1676)
The amount of local wifi clients is currently counted by two different
ways:

* asking the kernel wifi layer for the number of of clients on 2.4GHz and
  5GHz band
* asking batman-adv for the number of non-timed out entries in the local
  translation table with WiFi flag

The number of wifi24+wifi5 and the number of TT wifi client counts are
reported via respondd to various consumers. The ffrgb meshviewer is
displaying these values as:

* 2,4 GHz: wifi24
* 5 GHz: wifi5
* other: (TT local wifi+non-wifi clients) - (wifi24 + wifi5)

But the local translation table is holding entries much longer than the
wifi layer. It can therefore easily happen that a wifi client disappears in
the kernel wifi layer and batman-adv still has the entry stored in the
local TT.

The ffrgb meshviewer would then show this count in the category "other".
This often results in confusions because "other" is usually for ethernet
clients. And nodes with a frequently disappearing larger group of clients
(near bus stations or larger intersections) often show most clients under
the group "other" even when this devices doesn't have a LAN ethernet port.

It is better for presentation to calculate the number of total wifi clients
by summing up wifi24 + wifi5. And getting the number of total clients (non
wifi + wifi) by adding the result of the previous calculation to the sum of
non-wifi client in the local batman-adv translation table.

Fixes: 89a9d8138c ("gluon-mesh-batman-adv-core: Announce client count by frequency")
Reported-by: Pascal Wettin <p.wettin@gmx.de>
2019-03-16 13:37:49 +01:00
David Bauer
f52bd99e71 gluon-mesh-batman-adv: use libnl-tiny to get IPv6 addresses (#1616) 2019-02-17 19:53:24 +01:00
Matthias Schiffer
6d4d4792d5
gluon-mesh-*: do not count wifi clients/neighbours inactive for more than 60s 2018-11-18 11:45:16 +01:00
Matthias Schiffer
f61d252361
gluon-mesh-batman-adv: respondd: do not count batadv clients inactive for more than 60s 2018-11-17 20:07:00 +01:00
Matthias Schiffer
897ee73d14
gluon-mesh-batman-adv: respondd: remove incorrect field width limits
At least the ifindex and the flags fields can be larger than 0xff.

Fixes #1523
2018-09-01 11:12:22 +02:00
Sven Eckelmann
3ef28a4684 gluon-client-bridge: Revert "move IPv4 local subnet route to br-client (#1312)"
The commit b3762fc61c ("gluon-client-bridge: move IPv4 local subnet route
to br-client (#1312)") moves the IPv4 prefix from the local-port interface
to br-client. A client requesting an IPv4 connection to the IPv4 anycast
address of the node (the device running gluon) will create following
packets:

1. ARP packet from client to get the MAC of the mac address of the anycast
   IPv4 address
2. ARP reply from node to client with the anycast MAC address for the IPv4
   anycast address
3. IPv4 packet from client which requires reply (for example ICMP echo
   request)
4. ARP request for the client MAC address for its IPv4 address in prefix4
   (done with the mac address of br-client and transmitted over br-client)
5. IPv4 packet from node (transmitted over br-client with br-client MAC
   address) as reply for the client IPv4 packet (for example ICMP echo
   reply)

The step 4 and 5 are problematic here because packets use the node specific
MAC addresses from br-client instead of the anycast MAC address. The client
will receive the ARP packet with the node specific MAC address and change
their own neighbor IP (translation) table. This will for example break the
access to the status page to the connected device or the anycast DNS
forwarder implementation when the client roams to a different node.

This reverts commit b3762fc61c and adds an
upgrade code to remove local_node_route on on existing installations.
2018-07-22 16:42:41 +02:00
Sven Eckelmann
fc59d5208d gluon-mesh-batman-adv: Drop IPv4 anycast related packets from/to bat0
The commit b3762fc61c ("gluon-client-bridge: move IPv4 local subnet route
to br-client (#1312)") moves the IPv4 prefix from the local-port interface
to br-client. A client requesting an IPv4 connection to the IPv4 anycast
address of the node (the device running gluon) will create following
packets:

1. ARP packet from client to get the MAC of the mac address of the anycast
   IPv4 address
2. ARP reply from node to client with the anycast MAC address for the IPv4
   anycast address
3. IPv4 packet from client which requires reply (for example ICMP echo
   request)
4. ARP request for the client MAC address for its IPv4 address in prefix4
   (done with the mac address of br-client and transmitted over br-client)
5. IPv4 packet from node (transmitted over br-client with br-client MAC
   address) as reply for the client IPv4 packet (for example ICMP echo
   reply)

The step 4 is extremely problematic here. ARP replies with the anycast IPv4
address must not be submitted or received via bat0 - expecially not when it
contains an node specific MAC address as source. When it is still done then
the wrong MAC address is stored in the batadv DAT cache and ARP packet is
maybe even forwarded to clients. This latter is especially true for ARP
requests which are broadcast and will be flooded to the complete mesh.

Clients will see these ARP packets and change their own neighbor IP
(translation) table. They will then try to submit the packets for IPv4
anycast addresses to the complete wrong device in the mesh. This will for
example break the access to the status page to the connected device or the
anycast DNS forwarder implementation. Especially the latter causes extreme
latency when clients try to connect to server using a domain name or even
breaks the connection setup process completely. Both are caused by the
unanswered DNS requests which at first glance look like packet loss.

An node must therefore take care of:

* not transmitting ARP packets related to the anycast IPv4 address over
  bat0
* drop ARP packets related to the anycast IPv4 when they are received on
  bat0 from a still broken node
* don't accept ARP packets related to the anycast IPv4 replies on local
  node when it comes from bat0

Fixes: b3762fc61c ("gluon-client-bridge: move IPv4 local subnet route to br-client (#1312)")
2018-07-22 16:42:41 +02:00
Matthias Schiffer
1f7ed28b76
gluon-core: set VXLAN/legacy mode in site config
In multidomain setups, VXLAN is enabled by default, but can be disabled in
domain configs using the mesh/vxlan option. In single domain setups, the
mesh/vxlan option is mandatory.

The UCI option for legacy mode is removed.

Fixes #1364
2018-04-27 18:05:50 +02:00
Matthias Schiffer
994c94918a
treewide: automatically set SECTION and CATEGORY for Gluon packages 2018-04-14 00:01:04 +02:00
Matthias Schiffer
74f4119c1b
treewide: add support for building kernel modules used by Gluon into the kernel 2018-04-13 17:32:20 +02:00
Matthias Schiffer
25b32ec2fe
treewide: move sysctl settings to /etc/sysctl.d
net.ipv6.conf.br-client.forwarding is moved from gluon-client-bridge to
gluon-mesh-batman-adv, as the setting is not useful with non-bridged
protocols.
2018-04-13 14:41:01 +02:00
Matthias Schiffer
c80c294b3f
gluon-mesh-batman-adv: increase bridge multicast querier robustness to 9
The RFC standard multicast querier interval is 120s. Our querier uses in
interval of 20s for better support of roaming clients, but our robustness
setting of 3 leads to external queriers using the standard interval to be
timeout after only 60s, leading to frequent "querier appeared/disappeared"
messages. Increase robustness so that external queriers with any interval
<180s are supported.
2018-03-11 12:36:54 +01:00
Matthias Schiffer
60522ee253
treewide: move package Makefile boilerplate to gluon.mk 2018-03-08 19:49:41 +01:00
Matthias Schiffer
934221b86f
treewide: remove redundant definitions from package Makefiles 2018-03-07 21:23:41 +01:00
T-X
b3762fc61c gluon-client-bridge: move IPv4 local subnet route to br-client (#1312)
This patch moves the prefix4 subnet route from the local-node veth
device to br-client (while keeping the next node ipv4 address on the
local node device).

This is in preparation to allow routing over the br-client interface
later.
2018-02-16 00:00:12 +01:00
Matthias Schiffer
7ccdacd294
treewide: rework check_site_lib.lua
In addition to significant internal differences in check_site_lib.lua (in
particular unifying error handling to a single place for the upcoming
multi-domain support), this changes the way fields are addressed in site
check scripts: rather than providing a string like 'next_node.ip6', the
path is passed as an array {'next_node', 'ip6'}.

Other changes in site check scripts:
* need_array and need_table now pass the full path to the sub fields to the
subcheck instead of the key and value
* Any check referring to a field inside a table implies that all higher
levels must be tables if they exist: a check for {'next_node', 'ip6'} adds
an implicit (optional) check for {'next_node'}, which allows to remove many
explicit checks for such tables
2018-01-19 10:12:43 +01:00
Sven Eckelmann
a267cc7ee7 gluon-mesh-batman-adv: Use genl helpers from libbatadv
Signed-off-by: Sven Eckelmann <sven@narfation.org>
2017-12-27 17:40:35 +01:00
Christof Schulze
1c1c9f8fc7
gluon-core: firewall rework, make base policy more restrictive
* gluon-core, gluon-client-bridge: introduce new firewall zone: local_client
 * gluon-core: put clients in local_client zone, introduce drop-zone,
   set dns-rules and zones
 * gluon-respondd: allow respondd on mesh
 * gluon-status-page-api: allow http input on mesh and client
2017-11-25 23:19:08 +01:00
Matthias Schiffer
9324d18fee
gluon-mesh-batman-adv: filter out all packages between bat0 and local-port
Filtering by MAC address won't filter out multicast packages like router
solicitations, causing uradvd to send out router advertisements with
maximum frequency (every 3 seconds) in active meshes, even when no local
client is actually interested in the advertisements.

Fixes #1230
2017-10-03 17:07:42 +02:00
lemoer
4899dda4af treewide: check for NULL after uci_alloc_context() (#1224) 2017-09-21 20:56:40 +02:00
Matthias Schiffer
ee6afaced9
treewide: use new gluon.site Lua library
Some files have received some additional refactoring.
2017-08-11 22:07:34 +02:00
Matthias Schiffer
8dbf3ea568
gluon-mesh-batman-adv: fix radvd start with dns.servers, but without next_node.ip config 2017-08-11 20:56:06 +02:00
Matthias Schiffer
12ec6ab2bc
gluon-mesh-batman-adv: use new gluon.site library to avoid 'or {}' syntax 2017-08-08 13:53:20 +02:00
Matthias Schiffer
a76eaa5c45
gluon-mesh-batman-adv: preserve gw_mode on upgrades
When a Gluon node is used to connect to an uplink router/DHCP server (for
example in deployments without VPN tunnels), the gw_mode must be set to
server; this should be preserved on upgrades.

Fixes #1196
2017-07-25 23:49:11 +02:00
Steffen Förster
582d09615b
gluon-mesh-batman-adv: enable routing algorithm configuration through site.conf
[Matthias Schiffer: move to proto_gluon_bat0_setup() and default to BATMAN_IV]
2017-07-19 17:58:07 +02:00
Matthias Schiffer
08e667ba2e
gluon-client-bridge: add default next-node MAC address
The next-node MAC address doesn't need to be unique in different
communities, so we can as well add a default value.
2017-06-26 22:48:45 +02:00
Matthias Schiffer
1ed87c6df4
gluon-mesh-batman-adv: enable bridge learning on bat0 again
Reverts d5829d87be ("gluon-mesh-batman-adv-core: disable bridge port
learning on bat0").

Fixes #1121
2017-05-12 15:43:31 +02:00
Christof Schulze
5bf3c895d0 gluon-mesh-batman-adv: announce dns server if dns cache was configured (#1105) 2017-04-27 21:11:23 +02:00
Matthias Schiffer
e45c30330d
gluon-mesh-batman-adv: refactor interface management
We now create bat0 and primary0 independently of the lower mesh interfaces,
making the whole setup a lot more robust. In particular:

- we can't accidentially destroy primary0 because of concurrent setup and
  teardown runs of different interfaces
- bat0 will always exist, even when no mesh interfaces are up (e.g. no link
  on wired mesh)
- interfaces going down and up again will never tear down the whole of
  batman-adv
- we can enable and disable bat0 independently of the lower interface
  states
2017-04-12 19:23:08 +02:00
Matthias Schiffer
4ca67dcca5
gluon-mesh-batman-adv-*: unify into a single source package
For simplicity, we don't use different MTUs for compat 14 and 15 anymore,
there's no harm in using 1532 for batman-adv-legacy as well.
2017-04-12 04:22:45 +02:00