Commit Graph

9 Commits

Author SHA1 Message Date
Matthias Schiffer
e305a8c019
gluon-mesh-batman-adv: increase bridge multicast querier robustness to 9
The RFC standard multicast querier interval is 120s. Our querier uses in
interval of 20s for better support of roaming clients, but our robustness
setting of 3 leads to external queriers using the standard interval to be
timeout after only 60s, leading to frequent "querier appeared/disappeared"
messages. Increase robustness so that external queriers with any interval
<180s are supported.
2018-03-11 12:52:55 +01:00
Matthias Schiffer
9cecb1e836
gluon-mesh-batman-adv: filter out all packages between bat0 and local-port
Filtering by MAC address won't filter out multicast packages like router
solicitations, causing uradvd to send out router advertisements with
maximum frequency (every 3 seconds) in active meshes, even when no local
client is actually interested in the advertisements.

Fixes #1230
2017-10-03 17:18:27 +02:00
Matthias Schiffer
973c6dd479
gluon-mesh-batman-adv: fix radvd start with dns.servers, but without next_node.ip config 2017-08-11 20:58:41 +02:00
Matthias Schiffer
c197d028ec
gluon-mesh-batman-adv: preserve gw_mode on upgrades
When a Gluon node is used to connect to an uplink router/DHCP server (for
example in deployments without VPN tunnels), the gw_mode must be set to
server; this should be preserved on upgrades.

Fixes #1196
2017-07-25 23:56:03 +02:00
Steffen Förster
826ac88493
gluon-mesh-batman-adv: enable routing algorithm configuration through site.conf
[Matthias Schiffer: move to proto_gluon_bat0_setup() and default to BATMAN_IV]
2017-07-19 18:12:29 +02:00
Matthias Schiffer
1ed87c6df4
gluon-mesh-batman-adv: enable bridge learning on bat0 again
Reverts d5829d87be ("gluon-mesh-batman-adv-core: disable bridge port
learning on bat0").

Fixes #1121
2017-05-12 15:43:31 +02:00
Christof Schulze
5bf3c895d0 gluon-mesh-batman-adv: announce dns server if dns cache was configured (#1105) 2017-04-27 21:11:23 +02:00
Matthias Schiffer
e45c30330d
gluon-mesh-batman-adv: refactor interface management
We now create bat0 and primary0 independently of the lower mesh interfaces,
making the whole setup a lot more robust. In particular:

- we can't accidentially destroy primary0 because of concurrent setup and
  teardown runs of different interfaces
- bat0 will always exist, even when no mesh interfaces are up (e.g. no link
  on wired mesh)
- interfaces going down and up again will never tear down the whole of
  batman-adv
- we can enable and disable bat0 independently of the lower interface
  states
2017-04-12 19:23:08 +02:00
Matthias Schiffer
4ca67dcca5
gluon-mesh-batman-adv-*: unify into a single source package
For simplicity, we don't use different MTUs for compat 14 and 15 anymore,
there's no harm in using 1532 for batman-adv-legacy as well.
2017-04-12 04:22:45 +02:00