Commit Graph

20 Commits

Author SHA1 Message Date
Matthias Schiffer
b262b72563 gluon-mesh-batman-adv: adjust to removal of batman-adv UCI config 2019-10-30 00:06:14 +01:00
Matthias Schiffer
5b97d36c7e gluon-mesh-batman-adv: remove gluon-mesh-batman-adv-14 2019-09-25 21:57:52 +02:00
Linus Lüssing
302a795189 Revert "gluon-mesh-batman-adv: reenable batman-adv multicast optimizations"
This reverts commit 9b1eb40fe7.

With the batman-adv v2019.2 upgrade reverted (c1a7733956), the batman-adv
multicast-to-multi-unicast feature is not available yet. Without that it is
going to be very unlikely of the batman-adv multicast optimizations to
take effect. E.g. some outdated nodes would disable it.

To avoid confusion and diversion with a few communities having it enabled
and most implicitly deactivated, just deactivate it for all for now
until batman-adv is updated to v2019.2 or greater again.
2019-09-21 23:28:12 +02:00
Linus Lüssing
cb899874dc
gluon-mesh-batman-adv: allow installing mesh-batman-adv-14 and -15 at the same time
The new routing_algo site.conf value BATMAN_IV_LEGACY is introduced. With
these changes, the routing_algo setting becomes mandatory.

Signed-off-by: Linus Lüssing <linus.luessing@c0d3.blue>
2019-08-22 20:09:10 +02:00
Matthias Schiffer
ecc8ebc8ed
treewide: move ebtables filter definitions from files to luasrc 2019-06-18 19:52:33 +02:00
bobcanthelpyou
4249d65af7 treewide: fix luacheck warnings 2019-06-16 22:51:53 +02:00
Linus Lüssing
9b1eb40fe7 gluon-mesh-batman-adv: reenable batman-adv multicast optimizations
Several fixes and enhancements related to multicast were added upstream
in batman-adv. So let's give the batman-adv multicast optimizations
another go.

Signed-off-by: Linus Lüssing <linus.luessing@c0d3.blue>
2019-06-07 15:16:40 +02:00
Sven Eckelmann
3ef28a4684 gluon-client-bridge: Revert "move IPv4 local subnet route to br-client (#1312)"
The commit b3762fc61c ("gluon-client-bridge: move IPv4 local subnet route
to br-client (#1312)") moves the IPv4 prefix from the local-port interface
to br-client. A client requesting an IPv4 connection to the IPv4 anycast
address of the node (the device running gluon) will create following
packets:

1. ARP packet from client to get the MAC of the mac address of the anycast
   IPv4 address
2. ARP reply from node to client with the anycast MAC address for the IPv4
   anycast address
3. IPv4 packet from client which requires reply (for example ICMP echo
   request)
4. ARP request for the client MAC address for its IPv4 address in prefix4
   (done with the mac address of br-client and transmitted over br-client)
5. IPv4 packet from node (transmitted over br-client with br-client MAC
   address) as reply for the client IPv4 packet (for example ICMP echo
   reply)

The step 4 and 5 are problematic here because packets use the node specific
MAC addresses from br-client instead of the anycast MAC address. The client
will receive the ARP packet with the node specific MAC address and change
their own neighbor IP (translation) table. This will for example break the
access to the status page to the connected device or the anycast DNS
forwarder implementation when the client roams to a different node.

This reverts commit b3762fc61c and adds an
upgrade code to remove local_node_route on on existing installations.
2018-07-22 16:42:41 +02:00
Matthias Schiffer
25b32ec2fe
treewide: move sysctl settings to /etc/sysctl.d
net.ipv6.conf.br-client.forwarding is moved from gluon-client-bridge to
gluon-mesh-batman-adv, as the setting is not useful with non-bridged
protocols.
2018-04-13 14:41:01 +02:00
Matthias Schiffer
c80c294b3f
gluon-mesh-batman-adv: increase bridge multicast querier robustness to 9
The RFC standard multicast querier interval is 120s. Our querier uses in
interval of 20s for better support of roaming clients, but our robustness
setting of 3 leads to external queriers using the standard interval to be
timeout after only 60s, leading to frequent "querier appeared/disappeared"
messages. Increase robustness so that external queriers with any interval
<180s are supported.
2018-03-11 12:36:54 +01:00
T-X
b3762fc61c gluon-client-bridge: move IPv4 local subnet route to br-client (#1312)
This patch moves the prefix4 subnet route from the local-node veth
device to br-client (while keeping the next node ipv4 address on the
local node device).

This is in preparation to allow routing over the br-client interface
later.
2018-02-16 00:00:12 +01:00
Christof Schulze
1c1c9f8fc7
gluon-core: firewall rework, make base policy more restrictive
* gluon-core, gluon-client-bridge: introduce new firewall zone: local_client
 * gluon-core: put clients in local_client zone, introduce drop-zone,
   set dns-rules and zones
 * gluon-respondd: allow respondd on mesh
 * gluon-status-page-api: allow http input on mesh and client
2017-11-25 23:19:08 +01:00
Matthias Schiffer
ee6afaced9
treewide: use new gluon.site Lua library
Some files have received some additional refactoring.
2017-08-11 22:07:34 +02:00
Matthias Schiffer
8dbf3ea568
gluon-mesh-batman-adv: fix radvd start with dns.servers, but without next_node.ip config 2017-08-11 20:56:06 +02:00
Matthias Schiffer
a76eaa5c45
gluon-mesh-batman-adv: preserve gw_mode on upgrades
When a Gluon node is used to connect to an uplink router/DHCP server (for
example in deployments without VPN tunnels), the gw_mode must be set to
server; this should be preserved on upgrades.

Fixes #1196
2017-07-25 23:49:11 +02:00
Steffen Förster
582d09615b
gluon-mesh-batman-adv: enable routing algorithm configuration through site.conf
[Matthias Schiffer: move to proto_gluon_bat0_setup() and default to BATMAN_IV]
2017-07-19 17:58:07 +02:00
Matthias Schiffer
1ed87c6df4
gluon-mesh-batman-adv: enable bridge learning on bat0 again
Reverts d5829d87be ("gluon-mesh-batman-adv-core: disable bridge port
learning on bat0").

Fixes #1121
2017-05-12 15:43:31 +02:00
Christof Schulze
5bf3c895d0 gluon-mesh-batman-adv: announce dns server if dns cache was configured (#1105) 2017-04-27 21:11:23 +02:00
Matthias Schiffer
e45c30330d
gluon-mesh-batman-adv: refactor interface management
We now create bat0 and primary0 independently of the lower mesh interfaces,
making the whole setup a lot more robust. In particular:

- we can't accidentially destroy primary0 because of concurrent setup and
  teardown runs of different interfaces
- bat0 will always exist, even when no mesh interfaces are up (e.g. no link
  on wired mesh)
- interfaces going down and up again will never tear down the whole of
  batman-adv
- we can enable and disable bat0 independently of the lower interface
  states
2017-04-12 19:23:08 +02:00
Matthias Schiffer
4ca67dcca5
gluon-mesh-batman-adv-*: unify into a single source package
For simplicity, we don't use different MTUs for compat 14 and 15 anymore,
there's no harm in using 1532 for batman-adv-legacy as well.
2017-04-12 04:22:45 +02:00