gluon/targets/ipq806x-generic
David Bauer 15ef885836
ipq40xx: switch Wave2 firmware to -ct (#2541)
Use the candelatech firmware for the QCA Wave-2 firmware.

The Qualcomm firmware used for the IPQ401x chip in OpenWrt in 22.03
is experiencing heavily degraded performance due to excessive
retransmits when using A-MSDU. Disabling VHT modes or switching to the
candelatech firmware circumvents this issue.

Apply the same to other Wave-2 platforms in order to keep consistency
with upstream.

Wave-1 chips do not support mesh modes with the -ct firmware, so keep
using the QCA firmware in their case.

Signed-off-by: David Bauer <mail@david-bauer.net>
2022-06-05 11:55:25 +02:00

29 lines
765 B
Plaintext

-- The QCA9980 was discontinued by Qualcomm. It didn't receive any firmware-update for over 4 years.
-- See https://github.com/kvalo/ath10k-firmware/tree/master/QCA99X0/hw2.0
-- 802.11s was never implemented for the chip's firmware. It will most likely be broken forever.
-- The QCA9984 on the other hand works fine for 11s meshes on both bands.
local QCA9980_PACKAGES = {'-kmod-ath10k', 'kmod-ath10k-ct', '-ath10k-firmware-qca99x0', 'ath10k-firmware-qca99x0-ct'}
local QCA9984_PACKAGES = {}
--
-- QCA9980
--
-- TP-Link
device('tp-link-archer-c2600', 'tplink_c2600', {
packages = QCA9980_PACKAGES,
broken = true,
})
--
-- QCA9984
--
-- NETGEAR
device('netgear-nighthawk-x4s-r7800', 'netgear_r7800', {
factory_ext = '.img',
packages = QCA9984_PACKAGES,
})